Know that every lane got the right dose before the section is plucked.
Spray Score fits a small sensor to the knapsack and power sprayers estates already use. It checks each lane against the sprayer recipe in the Plant Protection Code, shows the supervisor which lanes were missed or overdosed, and keeps a section off the plucking programme until its waiting period has passed.
- Product
- Fenpyroximate 5 EC · waiting period 7 days
- Sprayed
- 23 Nov · Squad B · 6 knapsacks
- Measured
- 184 L/ha · recipe 150–175 L/ha
- Coverage
- 46 of 48 lanes
The register records what left the store, not what reached the bush
The Plant Protection Code already sets the recipe. A knapsack with an NMD nozzle should discharge about 0.45 litres a minute, with the worker walking about 40 feet a minute and covering one row on either side, for 150–175 litres a hectare in a plucking field.
Whether a lane actually gets that depends on a worn nozzle, a tired arm on the pump, or a quick walk on the last lane before lunch. A supervisor with three squads can watch only a few workers at a time.
The tank mix for section 14B is issued against the slip: enough product for 2.4 hectares.
Six workers spray 48 lanes. One nozzle is worn and runs 18% fast. Two lanes in the far corner are missed when the squad breaks to refill.
Walks part of 14B and part of 16A and checks three workers. Both look fine.
The register entry is written from the issue slip: 14B, 2.4 ha, Fenpyroximate, 400 litres. On paper, it's correct.
The plucking programme sends a gang to 14B on 29 Nov, a day before the 7-day waiting period ends. The two missed lanes become the mite patch the next round has to chase.
An illustrative day, drawn from the challenge statement and the Tea Board's Plant Protection Code (Ver. 19.0, April 2026). We'll walk a real spray round with a TRA member estate during discovery.
The margin for error is shrinking. The EU revised its residue limits for three insecticides used in Assam tea, effective 2025 and 2026, and nearly 40 million kg of Assam tea goes to the EU and UK each year (The Assam Tribune, June 2025).
The Code, the registers and the advisory visit are in place. The spray itself is not yet measured.
Most of what a safe spray round needs already works. Spray Score builds on each part and adds the one reading that is missing: what left the nozzle, on which lane.
The Plant Protection Code
The Code sets a recipe for each sprayer (Table 8), a waiting period for each product (Chapter 9) and the records every plantation must keep.
The estate's spray and calibration registers
Estates record the formulations they use and how their spray equipment is maintained and calibrated.
TRA advisory visits
TRA's advisory officers check formulation use in each garden during their mandatory visits.
TRA's ACLIVIA leaf test
TRA's rapid kit, being validated with CDAC and partners, tests green leaf for unapproved pesticides at the factory.
What's missing is a reading from the sprayer itself. A supervisor sees a few workers at a time, and the register is written from the store's issue slip, so a worn nozzle, a missed lane or a section plucked a day early shows up only later. Spray Score brings the Code's recipe, the registers, the plucking programme and the advisory visit into one workflow for each spray round.
Plant Protection Code Ver. 19.0 (April 2026), Tea Board India. ACLIVIA as reported by PTI in July 2024.
Three ideas, one spray round
The kit measures the two things that set the dose: what the nozzle puts out, and how fast the worker walks.
Table 8 of the Plant Protection Code gives each sprayer a recipe: nozzle, discharge, walking speed, rows covered and litres per hectare. The dose on a lane follows from three of those. The kit measures discharge with a flow sensor and pace from the time between turns at the headland, so every lane gets a dose against the recipe band.
A one-minute check each morning catches worn nozzles before the round starts. The same figures feed a weekly squad score. A worker's own readings are seen only by them and their supervisor.
| Kit SK-0219 | Recipe | Measured |
|---|---|---|
| Nozzle discharge | 0.45 L/min | 0.53 L/min |
| Pressure | ≈ 2.8 bar | 2.8 bar |
| Walking pace | 12.2 m/min | 11.1 m/min |
| Dose, lanes 17–24 | 150–175 L/ha | 240 L/ha |
A section goes on the plucking programme only when every lane is sprayed and its waiting period has passed.
Chapter 9 of the Code lists a pre-harvest interval for every approved product. Spray Score knows when each lane was sprayed, and with what, so it can say on which day each section is safe to pluck.
A re-sprayed lane restarts its own clock, and the gate shows it, so the plucking supervisor can leave those lanes for the next round. Plucking inside the interval needs the manager's sign-off and a written reason, both kept in the record.
The spray and calibration records the Code asks for, filled in from measurements.
The Code asks every plantation to keep records of the formulations it uses and of how its spray equipment is maintained and calibrated. TRA's advisory officers check formulation use on their visits.
Spray Score fills both registers from the kits, with the measured litres, the lanes covered and each morning's nozzle check. If the estate agrees, the advisory officer sees the register before the visit. Anonymised figures across estates show how far real rounds sit from the recipe, which is field evidence for Tocklai's own advice.
Built around the Code, the sprayers and the estate's own routine
- The Plant Protection Code stays the rulebookRecipes and waiting periods are loaded from the current version and updated when the Tea Board issues the next one.
- The sprayers stayThe kit fits inline between pump and lance on knapsack, power and battery sprayers, with hose adapters for common models.
- The plucking programme stays the estate'sCleared and blocked sections go to the muster, or to the estate's software, as a list or a file.
- TRA advisory visits carry on as nowThe register follows the format the advisory officer already checks, and is shared only if the estate agrees.
Try the working prototype
Choose a role. All three work on the same spray records, so a re-spray in the field changes what the manager and TRA see.